{"id":4566,"date":"2020-07-31T13:54:15","date_gmt":"2020-07-31T11:54:15","guid":{"rendered":"https:\/\/hirox-europe.com\/?page_id=4566"},"modified":"2020-08-11T15:23:54","modified_gmt":"2020-08-11T13:23:54","slug":"faq","status":"publish","type":"page","link":"https:\/\/hirox-europe.com\/de\/support\/faq\/","title":{"rendered":"FAQ"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4566\" class=\"elementor elementor-4566\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-16b5509 elementor-section-full_width elementor-section-height-default elementor-section-height-default\" data-id=\"16b5509\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-93a608c\" data-id=\"93a608c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-743881e elementor-widget elementor-widget-heading\" data-id=\"743881e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-33ffa427 elementor-section-stretched elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"33ffa427\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;stretch_section&quot;:&quot;section-stretched&quot;,&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8e4a0b9\" data-id=\"8e4a0b9\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-073d935 elementor-widget elementor-widget-heading\" data-id=\"073d935\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Q1: Difference between digital and optical microscopy?<br>&nbsp;<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d607316 elementor-widget elementor-widget-text-editor\" data-id=\"d607316\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The HIROX Hiscope is a dedicated digital microscope, that is, there is no provision to observe the sample directly through the lens except with a digital camera.<\/p><p>Once that design decision had been made the system was optimized for the characteristics of the imaging sensor &#8211; a flat, 2-D array with a known readout rate, response curve, pixel size, etc.<\/p><p>In a conventional microscope the optics of the eye have to be figured into the design parameters and that requirement may be different from and potentially conflict with those that would produce optimal images with an electronic imaging sensor.<\/p><p>Because the HiScope has been designed only for digital imaging no compromises have had to be made to accommodate the eye&#8217;s optics. However, the system is, in fact, often able to take advantage of sight physiology and visual signal processing to provide unique observational capabilities, i.e. 3-D Rotational Microscopy.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ddddb44 elementor-section-stretched elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ddddb44\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;stretch_section&quot;:&quot;section-stretched&quot;,&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6a6a9f9\" data-id=\"6a6a9f9\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-74f6318 elementor-widget elementor-widget-heading\" data-id=\"74f6318\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Q2: Advantages of a digital microscope?<br>&nbsp;<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-598eec8 elementor-widget elementor-widget-text-editor\" data-id=\"598eec8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Many of the advantages of a digital microscope are related just to the digital output itself.<br \/>For one, since the image is presented on a monitor everyone sees the same thing at the same time. No more trying to describe the small defect in the upper left corner of the field of view or hoping that the next person looking through the microscope is not just seeing their eyelashes: The image can be immediately processed, captured, stored, measured and reviewed.<br \/><br \/>The processing can not only enhance the image quality but can also do such things as extend the Depth of Field (DoF &#8211; the amount of the depth in the image that is in sharp focus) by blending in focus information from several image planes.<br \/><br \/>But there are other advantages that come from the design directly: One notable quality of some of the lenses is their unusually large DoF. The DoF is several times that of a conventional or stereomicroscope at the same magnification &#8211; often millimeters rather than micrometers! Other advantages include unique lighting regimes and observational capabilities like dynamic oblique viewing not available in conventional microscope even if they have video capabilities.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-0ec36e2 elementor-section-stretched elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"0ec36e2\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;stretch_section&quot;:&quot;section-stretched&quot;,&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f4e3e05\" data-id=\"f4e3e05\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f4ec281 elementor-widget elementor-widget-heading\" data-id=\"f4ec281\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Q3: What about magnification?<br>&nbsp;<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aef61d5 elementor-widget elementor-widget-text-editor\" data-id=\"aef61d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The short answer is NO, 300x in a digital microscope is not the same as 300x in a conventional microscope.<\/p><p>Just as the magnification of an image photographed in a conventional microscope depends on the size of the final print, so too the magnification of a digital microscope image will be determined by the size of the monitor on which it is displayed.<\/p><p>With digital microscopy it is really more relevant to talk about Field of View (FOV) rather than magnification &#8211; a 500-micrometer sample viewed on a 15&#8243; computer display is much lower &#8220;mag&#8221; than the same sample viewed on a large screen with a video projector.<\/p><p>The question to ask is &#8220;What is the ratio of the size of the real object to its size in the digital image?&#8221; Generally, with a 15&#8243; to 17&#8243; monitor this works out to be roughly 40% to 60% of the magnification you would be accustomed to in a conventional microscope. That is, 1000x in a digital microscope would be approximately the same as 400x to 600x in a conventional microscope.<\/p><p>The HiScope nominal magnifications are given for display on a standard 15&#8243; computer monitor. Table 1 gives a range of FOV for different magnifications.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4327b0f elementor-section-stretched elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4327b0f\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;stretch_section&quot;:&quot;section-stretched&quot;,&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-ae24916\" data-id=\"ae24916\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c284385 elementor-widget elementor-widget-heading\" data-id=\"c284385\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Q4: What is the Field-of-View per magnification?<br>&nbsp;<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a37728d elementor-widget elementor-widget-image\" data-id=\"a37728d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/hirox-europe.com\/wp-content\/uploads\/2020\/07\/mag-chart-faq.jpg\" class=\"attachment-full size-full wp-image-4568\" alt=\"\" srcset=\"https:\/\/hirox-europe.com\/wp-content\/uploads\/2020\/07\/mag-chart-faq.jpg 600w, https:\/\/hirox-europe.com\/wp-content\/uploads\/2020\/07\/mag-chart-faq-300x200.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-35be927 elementor-section-stretched elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"35be927\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;stretch_section&quot;:&quot;section-stretched&quot;,&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8d47cfd\" data-id=\"8d47cfd\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-1da9374 elementor-widget elementor-widget-heading\" data-id=\"1da9374\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Q5: Analog or Digital?<br>&nbsp;<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f4a44cc elementor-widget elementor-widget-text-editor\" data-id=\"f4a44cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The choice of an analog video camera or digital one comes down to three main factors &#8211; display refresh rate, compatibility and cost.<\/p><p>Since microscopy is highly interactive, it is important to have the human interface to be as close to &#8220;realtime&#8221; as possible. &#8220;Realtime&#8221; has come to mean 25 to 30 frames per second (even motion pictures are 24 frame per second). The number is related to visual physiology &#8211; the critical flicker rate, the rate above which the image is perceived as being continuously presented.<\/p><p>Until quite recently, only true analog video cameras were capable of presenting data that quickly. NTSC analog video, when digitized is almost 30MB per second. Since the video standards are so widely accepted it is a simple matter to find compatible hardware a situation that does not yet exist in the digital image world where many imaging devices use interfaces that are far less common.<\/p><p>Except for the NTSC\/PAL dichotomy, a video recording made on one machine is certain to play on any other comparable machine. Until quite recently, digital cameras with a resolution higher than analog video (640&#215;480) that had a 30 frame per second output were quite expensive.<\/p><p>Our Hirox KH-1300\/7700 units, however have overcome many of the limitation previously encountered in streaming digital imaging. With a standard UXGA (1600&#215;1200) output, the camera can plug directly into a high resolution computer monitor.<br \/>What&#8217;s more, with new pixel shifting technology the field of view can be sub-pixel sampled to give images with 30 million pixels.<\/p><p>Even recording streaming digital signals is now a simple matter with the latest compression codecs.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-471a5ab elementor-section-stretched elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"471a5ab\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;stretch_section&quot;:&quot;section-stretched&quot;,&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7d84cf2\" data-id=\"7d84cf2\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-cb2a8fe elementor-widget elementor-widget-heading\" data-id=\"cb2a8fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Q6: What about system resolution?<br>&nbsp;<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e4df3aa elementor-widget elementor-widget-text-editor\" data-id=\"e4df3aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Resolution in a digital microscope system can refer to several very different things. This is unfortunate because of the confusion the question of &#8220;what is the resolution?&#8221; brings.<\/p>\n<p>First to consider: the resolution of the camera itself. This is sometimes expressed as some number of lines, i.e. 800 lines resolution, or given as the number of pixels in the camera array, i.e. 1600&#215;1200. For line resolution the measurement is for the number of black and white line pairs that could be resolved if the central, highest resolution portion of the display were extended across the whole screen.<\/p>\n<p>Pretty esoteric stuff since few people look at vertical black and white lines. The number is, though, a relative indication of how sharp the image will be &#8211; the higher the number the sharper the image that the camera is capable of producing. The case with high resolution digital cameras is almost straight forward since here all the pixels count- well most of them do anyway.<\/p>\n<p>A camera with 1600&#215;1200 sensor elements will make an image with 1600&#215;1200 pixels. There is a little fudging because of the way the color is derived (demosaicing), but that is another, also somewhat complicated story. With the pixel shifted image however there is none of the demosaicing and each pixel really sees a red and blue and green signal &#8211; almost as if it were a 3 three chip camera.<\/p>\n<p>Now to the microscope resolution part of the question:<\/p>\n<p>Because the microscope has a zoom capability and can magnify an object to different sizes, the resolution will be dependent on both the magnification and the resolving power of the lens. The resolution of lenses is ultimately dependent on the wavelength of light &#8211; in air you simply cannot see anything below about half the wavelength of the illuminating light no matter how good the lens is or how much it will magnify.<\/p>\n<p>Without getting too technical, the theoretical limit is about .33 micrometer laterally and about 1 micrometer vertically but the practical limit is usually a little higher, perhaps closer to 1 micrometer in the X\/Y and 5 micrometers or more in the Z for lower magnification lenses.<\/p>\n<p>In a perfect world, that would mean you need a minimum magnification of roughly 300x to be able to just resolve two 1-micrometer objects. In practical terms, samples rarely have the extreme contrast or other physical and optical properties necessary to allow that resolution at that magnification.<\/p>\n<p>There is also the distinction that needs to be made between resolving, which is more of a theoretical exercise, and in being able to &#8220;see&#8221; the resolution. Sampling theory and optical physics define the resolving power of the system but, in practical terms, the magnification needs to be probably three to five times or more higher than theory would predict in order to have enough information in the image to actually &#8220;see&#8221; the resolution.<\/p>\n<p>Higher magnification is indeed empty magnification but at least you will have the image spread across enough pixels to allow you to visually distinguish between adjacent objects.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>FAQ Q1: Difference between digital and optical microscopy?&nbsp; The HIROX Hiscope is a dedicated digital microscope, that is, there is no provision to observe the sample directly through the lens except with a digital camera. Once that design decision had been made the system was optimized for the characteristics of the imaging sensor &#8211; a &#8230; <a title=\"FAQ\" class=\"read-more\" href=\"https:\/\/hirox-europe.com\/de\/support\/faq\/\" aria-label=\"Mehr Informationen \u00fcber FAQ\">Weiterlesen<\/a><\/p>","protected":false},"author":5,"featured_media":0,"parent":19,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-4566","page","type-page","status-publish"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>FAQ - Hirox Europe<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/hirox-europe.com\/de\/support\/faq\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FAQ - Hirox Europe\" \/>\n<meta property=\"og:description\" content=\"FAQ Q1: Difference between digital and optical microscopy?&nbsp; The HIROX Hiscope is a dedicated digital microscope, that is, there is no provision to observe the sample directly through the lens except with a digital camera. Once that design decision had been made the system was optimized for the characteristics of the imaging sensor &#8211; a ... Weiterlesen\" \/>\n<meta property=\"og:url\" content=\"https:\/\/hirox-europe.com\/de\/support\/faq\/\" \/>\n<meta property=\"og:site_name\" content=\"Hirox Europe\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/hiroxeurope\/\" \/>\n<meta property=\"article:modified_time\" content=\"2020-08-11T13:23:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/hirox-europe.com\/wp-content\/uploads\/2020\/07\/mag-chart-faq.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@hiroxeurope\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"7\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/hirox-europe.com\\\/ja\\\/support\\\/faq\\\/\",\"url\":\"https:\\\/\\\/hirox-europe.com\\\/ja\\\/support\\\/faq\\\/\",\"name\":\"FAQ - Hirox Europe\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/hirox-europe.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/hirox-europe.com\\\/ja\\\/support\\\/faq\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/hirox-europe.com\\\/ja\\\/support\\\/faq\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/hirox-europe.com\\\/wp-content\\\/uploads\\\/2020\\\/07\\\/mag-chart-faq.jpg\",\"datePublished\":\"2020-07-31T11:54:15+00:00\",\"dateModified\":\"2020-08-11T13:23:54+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/hirox-europe.com\\\/ja\\\/support\\\/faq\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/hirox-europe.com\\\/ja\\\/support\\\/faq\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/hirox-europe.com\\\/ja\\\/support\\\/faq\\\/#primaryimage\",\"url\":\"https:\\\/\\\/hirox-europe.com\\\/wp-content\\\/uploads\\\/2020\\\/07\\\/mag-chart-faq.jpg\",\"contentUrl\":\"https:\\\/\\\/hirox-europe.com\\\/wp-content\\\/uploads\\\/2020\\\/07\\\/mag-chart-faq.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/hirox-europe.com\\\/ja\\\/support\\\/faq\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/hirox-europe.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Support\",\"item\":\"https:\\\/\\\/hirox-europe.com\\\/ja\\\/support\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"FAQ\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/hirox-europe.com\\\/#website\",\"url\":\"https:\\\/\\\/hirox-europe.com\\\/\",\"name\":\"Hirox Europe\",\"description\":\"3D Digital Microscope - Fast, Easy, High Quality\",\"publisher\":{\"@id\":\"https:\\\/\\\/hirox-europe.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/hirox-europe.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/hirox-europe.com\\\/#organization\",\"name\":\"Hirox Europe\",\"url\":\"https:\\\/\\\/hirox-europe.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/hirox-europe.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/hirox-europe.com\\\/wp-content\\\/uploads\\\/2020\\\/05\\\/hirox-europe-logo.png\",\"contentUrl\":\"https:\\\/\\\/hirox-europe.com\\\/wp-content\\\/uploads\\\/2020\\\/05\\\/hirox-europe-logo.png\",\"width\":512,\"height\":410,\"caption\":\"Hirox Europe\"},\"image\":{\"@id\":\"https:\\\/\\\/hirox-europe.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/hiroxeurope\\\/\",\"https:\\\/\\\/x.com\\\/hiroxeurope\",\"https:\\\/\\\/www.instagram.com\\\/hirox3d\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/hirox-europe\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/hiroxEU\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"FAQ - Hirox Europe","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/hirox-europe.com\/de\/support\/faq\/","og_locale":"de_DE","og_type":"article","og_title":"FAQ - Hirox Europe","og_description":"FAQ Q1: Difference between digital and optical microscopy?&nbsp; The HIROX Hiscope is a dedicated digital microscope, that is, there is no provision to observe the sample directly through the lens except with a digital camera. Once that design decision had been made the system was optimized for the characteristics of the imaging sensor &#8211; a ... Weiterlesen","og_url":"https:\/\/hirox-europe.com\/de\/support\/faq\/","og_site_name":"Hirox Europe","article_publisher":"https:\/\/www.facebook.com\/hiroxeurope\/","article_modified_time":"2020-08-11T13:23:54+00:00","og_image":[{"url":"https:\/\/hirox-europe.com\/wp-content\/uploads\/2020\/07\/mag-chart-faq.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_site":"@hiroxeurope","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"7\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/hirox-europe.com\/ja\/support\/faq\/","url":"https:\/\/hirox-europe.com\/ja\/support\/faq\/","name":"FAQ - Hirox Europe","isPartOf":{"@id":"https:\/\/hirox-europe.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/hirox-europe.com\/ja\/support\/faq\/#primaryimage"},"image":{"@id":"https:\/\/hirox-europe.com\/ja\/support\/faq\/#primaryimage"},"thumbnailUrl":"https:\/\/hirox-europe.com\/wp-content\/uploads\/2020\/07\/mag-chart-faq.jpg","datePublished":"2020-07-31T11:54:15+00:00","dateModified":"2020-08-11T13:23:54+00:00","breadcrumb":{"@id":"https:\/\/hirox-europe.com\/ja\/support\/faq\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/hirox-europe.com\/ja\/support\/faq\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/hirox-europe.com\/ja\/support\/faq\/#primaryimage","url":"https:\/\/hirox-europe.com\/wp-content\/uploads\/2020\/07\/mag-chart-faq.jpg","contentUrl":"https:\/\/hirox-europe.com\/wp-content\/uploads\/2020\/07\/mag-chart-faq.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/hirox-europe.com\/ja\/support\/faq\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/hirox-europe.com\/"},{"@type":"ListItem","position":2,"name":"Support","item":"https:\/\/hirox-europe.com\/ja\/support\/"},{"@type":"ListItem","position":3,"name":"FAQ"}]},{"@type":"WebSite","@id":"https:\/\/hirox-europe.com\/#website","url":"https:\/\/hirox-europe.com\/","name":"Hirox Europe","description":"3D Digital Microscope - Fast, Easy, High Quality","publisher":{"@id":"https:\/\/hirox-europe.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/hirox-europe.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/hirox-europe.com\/#organization","name":"Hirox Europe","url":"https:\/\/hirox-europe.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/hirox-europe.com\/#\/schema\/logo\/image\/","url":"https:\/\/hirox-europe.com\/wp-content\/uploads\/2020\/05\/hirox-europe-logo.png","contentUrl":"https:\/\/hirox-europe.com\/wp-content\/uploads\/2020\/05\/hirox-europe-logo.png","width":512,"height":410,"caption":"Hirox Europe"},"image":{"@id":"https:\/\/hirox-europe.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/hiroxeurope\/","https:\/\/x.com\/hiroxeurope","https:\/\/www.instagram.com\/hirox3d\/","https:\/\/www.linkedin.com\/company\/hirox-europe","https:\/\/www.youtube.com\/user\/hiroxEU"]}]}},"_links":{"self":[{"href":"https:\/\/hirox-europe.com\/de\/wp-json\/wp\/v2\/pages\/4566","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hirox-europe.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/hirox-europe.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/hirox-europe.com\/de\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/hirox-europe.com\/de\/wp-json\/wp\/v2\/comments?post=4566"}],"version-history":[{"count":8,"href":"https:\/\/hirox-europe.com\/de\/wp-json\/wp\/v2\/pages\/4566\/revisions"}],"predecessor-version":[{"id":4580,"href":"https:\/\/hirox-europe.com\/de\/wp-json\/wp\/v2\/pages\/4566\/revisions\/4580"}],"up":[{"embeddable":true,"href":"https:\/\/hirox-europe.com\/de\/wp-json\/wp\/v2\/pages\/19"}],"wp:attachment":[{"href":"https:\/\/hirox-europe.com\/de\/wp-json\/wp\/v2\/media?parent=4566"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}